ALFACOM ENGINEERING LTD.
Condensate Recovery and Specialised Steam Equipment
Specialised equipment for steam, condensate and feedwater systems includes condensate pumps, separators, sampling systems, injectors, mixers and heat exchangers. Start with the required function and system conditions.
Condensate Recovery and Specialised Steam Equipment · Illustrative catalogue image
THE PRODUCT RANGE
Explore the Range
Browse All Models & Technical Documents →
Explore the equipment and selection topics below, then review the detailed catalogue for the selected product.
Explore the model guidance and selection notes in English. Technical document buttons below open model-specific PDFs hosted on this website.
Model & Technical Document Index
Select the equipment family and model below. Review the application and model-specific document before requesting selection and a quotation.
Condensate Pumps & Pump-Trap Systems
Steam Moisture & Hydronic Separators
Sample Coolers
Steam Injectors & Humidification
Steam / Water Mixing & Washing
Feedwater, Flash Steam & Boiler-House Equipment
Equipment Details & Selection
Condensate Pumps & Pump-Trap Systems
ADCAMAT POP-LC · DN25–40
Pressure-operated mechanical pump for transferring compatible hot condensate and other liquids to a higher elevation or pressure.
Selection requires liquid load, filling head, motive-fluid pressure and total discharge backpressure. Verify the intended vented or closed-system arrangement.
ADCAMAT POPS · DN25–DN80×50
Pressure-operated condensate pump family using a float-controlled pumping cycle.
Specify the inlet and outlet sizes separately where different. Confirm filling head, motive supply, condensate load and discharge backpressure.
ADCAMAT POP-S · DN100
Larger pressure-operated pump for transferring compatible hot condensate and other liquids.
Use the DN100 pump document for capacity and dimensions. Include motive-fluid conditions, available filling head and the full return-line resistance.
ADCAMAT PPO14
Pressure-operated mechanical pump for compatible hot-liquid transfer, including condensate recovery.
Supply the condensate load, available filling head, motive supply and destination pressure. Confirm the system configuration against the pump instructions.
ADCAMAT PPA14
Mechanical pressure-operated pump for compatible hot condensate and liquid transfer.
Selection depends on motive-fluid pressure, filling head and discharge backpressure. Confirm the check-valve and vent or exhaust arrangement.
ADCAMAT PPA312
Pressure-operated mechanical pump for compatible hot-liquid transfer to a higher elevation or pressure.
Use the PPA312-specific capacity data and installation requirements. Provide the condensate load, motive supply and complete discharge duty.
ADCAMAT POPS-K · Simplex
Packaged condensate pumping unit combining one pump, a vented receiver and associated components on a common frame.
Specify the package duty and receiver requirements. Confirm the motive supply, available head, return pressure and the actual package scope.
ADCAMAT POPS-K · Duplex
Packaged condensate pumping arrangement with two pumps in parallel and a vented receiver.
Determine the required operating and standby arrangement explicitly. Confirm the capacity at actual motive pressure and discharge backpressure.
ADCAMAT POPS-K · Triplex
Packaged condensate pumping arrangement with three pumps in parallel and a vented receiver.
Define the required simultaneous duty and reserve capacity. Confirm receiver, motive supply, return-line pressure and package scope.
ADCAMAT APST · Selection & Sizing Guide
Application guide for assessing condensate drainage where low differential pressure can cause heat-exchanger stall.
This is a sizing resource rather than a separate pump model. Evaluate the control-valve operating range, exchanger pressure and return backpressure before selecting the drainage arrangement.
ADCAMAT APST · Automatic Pump & Steam Trap
Combined pumping and trapping equipment for condensate duties that can stall when differential pressure becomes insufficient.
Selection must include part-load conditions as well as full load. Provide exchanger duty, steam pressure variation, return backpressure and installation head.
Steam Moisture & Hydronic Separators
S16S · Centrifugal Moisture Separator
Moisture separator for steam or compressed-air pipelines.
Separated condensate must be drained by a suitable steam or compressed-air trap. Confirm line size, flow, pressure, allowable pressure drop and drainage arrangement.
S25S · HV / VH Separator
Centrifugal moisture separator family for steam or compressed-air pipelines, in HV and VH arrangements.
Select the required pipe orientation explicitly and follow the corresponding dimensional drawing. Provide flow and operating conditions for sizing.
S25S · PN16–PN40 Separator
Centrifugal separator for removing entrained moisture from steam or compressed-air lines.
Use the applicable body and flange version. Confirm flow, pressure drop, mounting orientation and condensate drainage; flange designation alone is not an operating envelope.
S25S · PN63 Separator
Centrifugal separator family for steam and compressed-air moisture removal.
Use the PN63 model document and verify the actual pressure-temperature conditions. Include a suitable condensate drainage arrangement.
S25SS · Stainless Steel Separator
Centrifugal moisture separator for steam and compressed-air pipelines.
Confirm the selected construction, line orientation and operating conditions. Size the condensate drainage system for the separator duty.
SH25S · Horizontal Separator
Horizontal centrifugal moisture separator for steam or compressed-air pipelines.
Check the horizontal piping arrangement against the model drawing. Provide flow, operating pressure and allowable pressure drop, and specify suitable condensate drainage.
S30S · Baffle Separator
Baffle-type moisture separator for steam or compressed-air pipelines.
Expansion, impact and flow changes separate entrained droplets and heavier particles. Provide the operating duty and include a suitable drainage trap.
SF251/S · Separator & Strainer
Centrifugal moisture-separation equipment for steam and compressed-air pipelines.
Verify the selected separator and strainer arrangement, flow direction and maintenance access in the model document. Collected condensate requires suitable automatic drainage.
AS · Hydronic Air & Dirt Separator
Centrifugal air and dirt separator for hydronic heating or cooling water systems.
This is a hydronic-water application, distinct from steam moisture separation. Specify water flow, line size, operating conditions and installation location.
Sample Coolers
SC32 / SC132 · Sample Cooler
Sample cooler for reducing the temperature of compatible boiler-water or steam samples before analysis.
Specify sample flow, pressure and temperature together with cooling-water conditions. Follow the connection and safe sampling instructions.
SC32B / SC132B · Sample Cooler
Sample-cooling family with a screwed-cover arrangement for compatible boiler-water and steam sampling duties.
Confirm the specific model and its connection layout. Size using sample conditions and available cooling water rather than line size alone.
SC32F / SC132F · Sample Cooler
Sample-cooling family for compatible boiler-water or steam analysis duties.
Use the F-family document for construction and connection details. Confirm both sample-side and cooling-water conditions.
SC332 / SC532 · Sample Cooler
Sample-cooling family for compatible hot pressurised water or steam sampling applications.
Provide sample duty and cooling-water supply conditions. Verify the selected model, materials and installation arrangement in its technical document.
Steam Injectors & Humidification
SI20 · DN20 Steam Injector
Direct steam injector for heating liquids in tanks or flowing-liquid applications.
Confirm liquid compatibility with direct steam contact, required heat input and available steam conditions. Size and install for the intended vessel and liquid circulation.
SI115 · DN15 Steam Injector
Steam injector for direct-contact liquid heating duties.
Provide vessel geometry, liquid volume and properties, temperature rise and required heating time. Confirm steam conditions and the installation arrangement.
SI125 / SI140 · Steam Injectors
Steam injector families for direct-contact heating of compatible liquids.
Select the injector using heat duty, available steam pressure and the vessel arrangement. Confirm which of SI125 or SI140 is required.
DSH · Direct Steam Humidifier
Direct steam humidification equipment.
Provide airflow, inlet conditions, required humidity and available steam quality and pressure. Confirm distribution, condensate drainage and the required absorption distance for the application.
Steam / Water Mixing & Washing
ADCAMIX MX20 · Steam / Water Mixing Valve
Steam and water mixing equipment for hot-water supply duties.
Confirm the inlet steam and water conditions, required hot-water temperature and flow, and the complete outlet arrangement. Follow the operating and installation instructions.
ADCAMIX SG20 · Water Delivery Gun
Industrial water delivery gun recommended in the source for use with ADCAMIX MX20 steam/water mixing systems.
The lever controls flow and spray pattern. Verify the hose, connection and operating conditions as a complete washing arrangement; no quantified water-saving claim is assumed.
Feedwater, Flash Steam & Boiler-House Equipment
ADG · Atmospheric Semi-Deaerator
Atmospheric feedwater heating and semi-deaeration equipment for reducing dissolved gases in boiler feedwater.
This is a semi-deaeration process. Define the required residual-gas level and any further water-treatment requirements; confirm the tank, heating and venting arrangement.
ADCATHERM FCD · Flash Condensing Head
Mixing head for recovering heat from flash steam into boiler make-up water.
Confirm make-up water, condensate return, recirculating feedwater and vent connections. Size it as part of the complete feedwater and flash-recovery arrangement.
TDG · Thermal Deaerator
Thermal deaeration equipment for boiler feedwater treatment.
Provide feedwater duty, inlet conditions and gas-removal requirements. Verify the vessel, steam supply, venting and controls as one system.
BEX · Boiler Blowdown Expansion & Cooling Unit
Equipment for handling the expansion and cooling of boiler blowdown.
Specify boiler and blowdown conditions, discharge frequency and the receiving drain requirements. Confirm the cooling-water supply and installation arrangement.
BFT · Boiler Feedwater Tank
Feedwater tank for boiler-house water and condensate-recovery arrangements.
Specify storage requirement, feedwater demand, condensate return and make-up water. Confirm the heating, venting, instrumentation and package scope.
BV · Blowdown Vessel
Vessel for receiving boiler blowdown and accommodating pressure reduction and flashing.
Provide blowdown pressure, quantity and frequency, and the required outlet conditions. Verify the vent, drain and cooling arrangements.
HCC · Hot Condensate Cooler
Device for gradually cooling hot condensate before it mixes with a colder condensate return, helping reduce flash-steam collapse and associated hammering.
The source describes a hot-condensate coil surrounded by colder condensate. Provide both condensate duties, temperatures and return-line conditions.
LIPO · Condensate Lifting Pot
Condensate lifting pot for rising condensate to an elevated return line while moderating shocks associated with flash-steam collapse.
This is a lifting-pot arrangement, not a pressure-operated pump. Confirm the riser geometry, condensate duty, flash conditions and installation against the source drawing.
MAS · Steam Distribution Manifold
Manifold equipment for steam distribution and associated branch connections.
Specify the number and duty of branches, inlet conditions and required connections. Confirm isolation, drainage and the complete manifold scope.
EH · Exhaust Head
Exhaust-head equipment for steam vent or discharge arrangements.
Provide the expected steam and condensate discharge duty. Verify the vent piping, mounting and drainage arrangement for the installation.
RV · Flash Vessel
Flash vessel for separating flash steam from hot condensate as pressure is reduced.
Provide incoming condensate flow and pressure, vessel operating pressure and intended flash-steam use. Confirm the separated condensate drainage arrangement.
RVST · Flash Vessel with Trap
Flash-steam recovery vessel with an integrated trapping arrangement.
Define flash-steam demand, incoming condensate conditions and return-line backpressure. Verify the selected vessel and trap operating requirements together.
Heat Exchangers & Heating Coils
ADCATHERM · Heat Exchanger Overview
Overview of heat-transfer equipment and application options in the ADCATHERM range.
This is a range resource. Select the actual exchanger using both fluid duties, temperatures, pressures and required heat load.
ADCATHERM PAT · Plate Heat Exchanger
Plate heat exchanger family for compatible heat-transfer duties.
Provide hot- and cold-side fluids, flow rates, inlet and required outlet temperatures, pressure limits and allowable pressure drop.
ADCATHERM STS · Shell & Tube Heat Exchanger
Shell-and-tube heat exchanger family for compatible process heat-transfer duties.
Specify both fluid duties, design conditions, materials and required heat load. Confirm the connection layout and maintenance requirements.
ADCATHERM R Series · Heating Coils
Heating-coil family for compatible vessel or process heating applications.
Provide tank geometry, process liquid, required temperature rise and heating time, and available heating-medium conditions.
ADCATHERM STH · Shell & Tube Heat Exchanger
Shell-and-tube heat exchanger family for compatible heating duties.
Use the STH-specific document for construction and layout. Size from the required heat duty and both fluid-side conditions.
ADCATHERM STV · Shell & Tube Heat Exchanger
Shell-and-tube heat exchanger family for compatible process heating applications.
Use the STV-specific construction and installation arrangement. Provide flow, temperature and pressure data for both sides of the exchanger.
APPLICATION BEFORE SPECIFICATION
Selection Starts with Your Application
Provide the duty, flow rate, pressures and temperatures. For condensate pumping, include return pressure and installation height; for heating or sampling equipment, include secondary-side conditions.
Catalogue & Technical Documents
Review the model-specific technical information and installation requirements. Send a specification, drawing or existing model reference if you need help selecting equipment.
Discuss Your Application
Send your requirements or a photo of the existing equipment for technical assistance and a quotation.
Availability and lead time are confirmed for the requested model and quantity.