ALFACOM ENGINEERING LTD.
ADCAPure — Clean Steam and Hygienic Equipment
The ADCAPure range from Valsteam ADCA includes stainless steel components for hygienic and aseptic applications: clean steam traps, regulators, control valves, ball valves, safety valves and pipeline accessories.
ADCAPure — Clean Steam and Hygienic Equipment · Illustrative catalogue image
THE PRODUCT RANGE
Explore the Range
Browse All Models & Technical Documents →
Explore the equipment and selection topics below, then review the detailed catalogue for the selected product.
Explore the model guidance and selection notes in English. Technical PDF buttons below open documents hosted on this website.
Model & Technical Document Index
Select the equipment family and model below. Review the application and model-specific document before requesting selection and a quotation.
Clean Steam Traps
Hygienic Pressure Regulators & Tank Blanketing
Hygienic & Aseptic Control Valves
Aseptic Safety Relief Valves
Hygienic Three-Piece Isolation Ball Valves
Hygienic Pipeline Ancillaries & Filtration
Clean Steam Separation, Sampling & Injection
Equipment Details & Selection
Clean Steam Traps
TSS7 · Clean Steam Thermostatic Trap
Stainless steel thermostatic trap and air vent for compatible clean or pure steam equipment and distribution lines.
Confirm the model connection, condensate load, differential pressure and permitted orientation. Specify the required surface finish, seals and documentation for the ordered configuration.
TSS6 · Clean Steam Thermostatic Trap
Compact stainless steel thermostatic trap and air vent for suitable reactors, sterilizers and clean steam lines.
Select the connection and thermostatic element using the condensate duty and required subcooling. Verify drainage orientation and the exact hygienic construction.
TSS6H · Clean Steam Thermostatic Trap
Thermostatic clean steam trap family with a sensitive element for condensate drainage close to steam saturation temperature.
Use the TSS6H capacity data and element specification. Confirm start-up and normal load, differential pressure and installation requirements.
TSS6A · Clean Steam Thermostatic Trap
Stainless steel thermostatic trap and air vent for compatible clean steam process equipment and distribution duties.
Use the TSS6A-specific construction and connection data. Confirm installation geometry, required condensate subcooling and the specified finish and seal materials.
Hygienic Pressure Regulators & Tank Blanketing
P130J · Hygienic Pressure Reducing Valve
Direct-acting diaphragm-sensing, balanced-plug pressure reducing regulator in the P130 family.
Specify the actual gas or liquid, inlet conditions, downstream pressure and flow range. Confirm wetted construction, connection and the required cleaning and documentation scope.
P130K · Hygienic Pressure Reducing Valve
Direct-acting diaphragm-sensing pressure reducing regulator for compatible high-purity process duties.
Confirm fluid compatibility, pressure range, flow and the exact construction. Specify required surface finish, seals, cleaning and documentation for the ordered configuration.
P160G · Angle-Design Pressure Reducing Valve
Direct-acting diaphragm-sensing regulator with an angle-design flow path for clean steam and other compatible fluids.
Specify inlet and downstream pressures, flow and temperature. Confirm the selected BPE connection, construction and regulator installation requirements.
P161 · Angle-Design Pressure Reducing Valve
Direct-acting diaphragm-sensing regulator with an angle-design flow path; spring or dome-loading versions are described in the source.
Confirm the selected loading arrangement, pressure range, flow and process connection. Specify finish, seals and cleaning requirements for the ordered configuration.
P163 · Inline Pressure Reducing Valve
Inline direct-acting diaphragm-sensing regulator for compatible clean steam and process-fluid pressure reduction.
The source describes spring and dome-loading options. Select the required pressure range, connection and installation arrangement explicitly.
PS163 · Inline Pressure Sustaining Valve
Inline direct-acting diaphragm-sensing regulator for upstream pressure control in compatible clean process duties.
Confirm spring or dome-loading, upstream set pressure, flow range and downstream conditions. Verify the exact body, connection and sealing configuration.
P130L · Low-Flow Hygienic Regulator
Direct-acting diaphragm-sensing pressure reducing regulator for smaller-flow high-purity gas or compatible liquid duties.
Specify the minimum and maximum flow as well as inlet and downstream pressures. Confirm material compatibility and any gas-specific cleaning requirements.
PS130 · Hygienic Pressure Sustaining Valve
Direct-acting diaphragm-sensing regulator for upstream pressure control in compatible high-purity gas or liquid systems.
Confirm the upstream set pressure, discharge conditions and flow range. Select wetted materials, seals and connection for the actual process.
P130H · Hygienic Pressure Reducing Valve
Direct-acting diaphragm-sensing, balanced-plug regulator for compatible high-purity gas and liquid pressure-reduction duties.
Confirm the pressure range, flow, connection and construction for the P130H version. Specify any required cleaning or material documentation.
P130G · Hygienic Pressure Reducing Valve
Direct-acting diaphragm-sensing, balanced-plug regulator for compatible high-purity gas and liquid duties.
Select using inlet and downstream pressure, flow and temperature. Confirm the specific fluid, wetted materials and required hygienic configuration.
P147 · Pilot-Operated Hygienic Regulator
Pilot-operated pressure reducing valve for compatible high-purity gas and liquid systems.
Select main valve and pilot together using the pressure and flow range. Confirm sensing arrangement, wetted materials and the required cleaning scope.
P173 · Clean Steam Pressure Reducing Valve
Direct-acting diaphragm-sensing regulator for pressure reduction in clean steam and other compatible fluids described in the source.
Use the P173 model data to confirm fluid compatibility, set range, connection and installation. Provide the complete operating and flow envelope.
PS173 · Clean Steam Pressure Sustaining Valve
Direct-acting diaphragm-sensing pressure sustaining valve for clean steam and other compatible process fluids.
Select for upstream pressure control and specify the downstream conditions. Verify the chosen construction and operating envelope for the actual fluid.
PS161 · Angle-Design Pressure Sustaining Valve
Direct-acting diaphragm-sensing pressure sustaining regulator with an angle-design flow path.
Confirm the upstream control duty, connection orientation, wetted construction and fluid compatibility. Do not substitute a downstream pressure reducing regulator for this function.
BKR2 · Tank Blanketing Regulator
Regulator for introducing a compatible blanketing gas into a tank vapour space as required by the selected arrangement.
Specify gas supply, tank operating pressure, demand and process compatibility. Qualify the complete tank pressure-control and venting arrangement separately.
BKV2 · Tank Venting Valve
Valve equipment for the venting side of a suitable tank blanketing and pressure-control arrangement.
Define the required venting function and capacity, tank pressure and discharge destination. Confirm the selected valve and the complete tank protection design.
BKRi2 · Tank Blanketing Regulator
Tank blanketing regulator in the BKRi2 family for an appropriate gas-covering arrangement.
Confirm the exact construction, supply conditions, tank set pressure and gas demand. Select the regulator as part of the complete tank control system.
BKVi2 · Tank Venting Valve
Tank venting valve in the BKVi2 family for an appropriate blanketing-system arrangement.
Confirm construction, pressure setting, venting capacity and discharge routing. The selected component must be qualified within the complete tank system.
Hygienic & Aseptic Control Valves
V928 · Two-Way Control Valve
Two-way process control-valve family within the ADCAPure range.
Specify fluid, flow, pressure drop, temperature and required shut-off. Confirm trim, actuator action, connection, finish and cleaning requirements for the selected construction.
V928 · Three-Way Control Valve
Three-way control-valve family for the compatible process duties described in the V928 document.
Specify the intended port function, branch flows and pressures. Confirm the exact mixing or diverting arrangement permitted for the selected valve.
V926A · Two-Way Aseptic Angle Control Valve
Single-seat two-way aseptic control-valve family with angle connections, for compatible liquid and gas duties.
Select the trim and actuator for flow, pressure drop and required shut-off. Confirm BPE connection, seals, wetted finish and the required cleaning or sterilisation duty.
V926H · Two-Way Hygienic Angle Control Valve
Single-seat two-way hygienic control-valve family with angle connections for compatible process liquid and gas duties.
Provide the process conditions and required fail position. Specify the selected BPE connection, trim, seals, surface finish and documentation.
Aseptic Safety Relief Valves
SRV6 · Aseptic Safety Relief Valve
Angle-connection safety relief valve for overpressure protection in compatible clean steam, gas or liquid applications.
Sizing requires the relieving case, medium, set pressure, required capacity, backpressure and discharge arrangement. Confirm the certification and documented capacity for the exact ordered configuration.
SRV8 · Aseptic Safety Relief Valve
Safety relief valve in the SRV8 aseptic family for compatible process overpressure-protection duties.
Define the required relieving case and verify the selected model, certified capacity, set pressure and backpressure limits. Confirm connections, seals and the required documentation.
Hygienic Three-Piece Isolation Ball Valves
M3HP · DN10–50 · DIN
Three-piece ball-valve family for compatible hygienic process isolation duties.
Use the M3HP DN10–50 DIN document for the selected body and end dimensions. Confirm seat and seal materials, wetted finish, drainability and cleaning requirements. Specify the exact end configuration; DIN and BPE versions are separate catalogue records. The source specifies fully open or fully closed isolation use, not modulating control.
M3HP · DN15–50 · BPE
Three-piece ball-valve family for compatible hygienic process isolation duties.
Use the M3HP DN15–50 BPE document for the selected body and end dimensions. Confirm seat and seal materials, wetted finish, drainability and cleaning requirements. Specify the exact end configuration; DIN and BPE versions are separate catalogue records. The source specifies fully open or fully closed isolation use, not modulating control.
M3HP · DN65–100 · BPE
Three-piece ball-valve family for compatible hygienic process isolation duties.
Use the M3HP DN65–100 BPE document for the selected body and end dimensions. Confirm seat and seal materials, wetted finish, drainability and cleaning requirements. Specify the exact end configuration; DIN and BPE versions are separate catalogue records. The source specifies fully open or fully closed isolation use, not modulating control.
M3HP · DN65–100 · DIN
Three-piece ball-valve family for compatible hygienic process isolation duties.
Use the M3HP DN65–100 DIN document for the selected body and end dimensions. Confirm seat and seal materials, wetted finish, drainability and cleaning requirements. Specify the exact end configuration; DIN and BPE versions are separate catalogue records. The source specifies fully open or fully closed isolation use, not modulating control.
M3HP · DN150 · BPE
Three-piece ball-valve family for compatible hygienic process isolation duties.
Use the M3HP DN150 BPE document for the selected body and end dimensions. Confirm seat and seal materials, wetted finish, drainability and cleaning requirements. Specify the exact end configuration; DIN and BPE versions are separate catalogue records. The source specifies fully open or fully closed isolation use, not modulating control.
M3H · DN10–50 · DIN
Three-piece ball-valve family for compatible hygienic process isolation duties.
Use the M3H DN10–50 DIN document for the selected body and end dimensions. Confirm seat and seal materials, wetted finish, drainability and cleaning requirements. Specify the exact end configuration; DIN and BPE versions are separate catalogue records. The source specifies fully open or fully closed isolation use, not modulating control.
M3H · DN65–100 · BPE
Three-piece ball-valve family for compatible hygienic process isolation duties.
Use the M3H DN65–100 BPE document for the selected body and end dimensions. Confirm seat and seal materials, wetted finish, drainability and cleaning requirements. Specify the exact end configuration; DIN and BPE versions are separate catalogue records. The source specifies fully open or fully closed isolation use, not modulating control.
M3H · DN65–100 · DIN
Three-piece ball-valve family for compatible hygienic process isolation duties.
Use the M3H DN65–100 DIN document for the selected body and end dimensions. Confirm seat and seal materials, wetted finish, drainability and cleaning requirements. Specify the exact end configuration; DIN and BPE versions are separate catalogue records. The source specifies fully open or fully closed isolation use, not modulating control.
M3H · DN15–50 · BPE
Three-piece ball-valve family for compatible hygienic process isolation duties.
Use the M3H DN15–50 BPE document for the selected body and end dimensions. Confirm seat and seal materials, wetted finish, drainability and cleaning requirements. Specify the exact end configuration; DIN and BPE versions are separate catalogue records. The source specifies fully open or fully closed isolation use, not modulating control.
M3H · DN150 · BPE
Three-piece ball-valve family for compatible hygienic process isolation duties.
Use the M3H DN150 BPE document for the selected body and end dimensions. Confirm seat and seal materials, wetted finish, drainability and cleaning requirements. Specify the exact end configuration; DIN and BPE versions are separate catalogue records. The source specifies fully open or fully closed isolation use, not modulating control.
Hygienic Pipeline Ancillaries & Filtration
ISFE · Sintered Filter Element
Sintered filtration-element family for an appropriate compatible filter-housing and process duty.
Select the element and housing together. Confirm retention grade, flow, pressure drop, material compatibility and cleaning or replacement requirements.
SMAN-63 · Hygienic Pressure Gauge
Pressure-indication equipment in the SMAN-63 hygienic gauge family.
Specify measuring range, process connection, fluid and temperature. Confirm the wetted interface, orientation and required hygienic construction.
SAV10 · Hygienic Start-Up Air Vent
Self-acting sanitary vent for removing air from suitable liquid-system start-up arrangements.
The valve closes when filled with liquid. It does not open under operating pressure and opens as liquid level falls only when pressure is also relieved. Confirm the start-up venting duty, mounting and discharge routing.
VBS17 · Hygienic Vacuum Breaker
Sanitary vacuum breaker that admits atmospheric air to relieve an unwanted vacuum in a compatible process system.
The source states that it is not a vacuum control valve. Confirm the required air-admission duty, set condition, process connection and installation arrangement.
ISH10I · Hygienic Steam Filter
Filter-housing family for an appropriate compatible hygienic steam or process filtration duty.
Select housing and element together using flow, pressure, temperature and retention requirements. Confirm drainability, cleaning procedure and documentation.
ISC20I · Culinary Steam Filter
Steam-filtration equipment for an appropriate culinary steam arrangement.
Specify steam conditions, flow and required filtration performance. Confirm the element, housing and process documentation; filtration alone does not establish complete system steam quality.
SRT10 · Hygienic Check Valve · BPE
Non-return valve family for compatible hygienic process service.
Confirm the exact BPE connection, permitted orientation, operating conditions and closure requirements. Verify seals, finish and cleaning compatibility.
SWS · Hygienic Sight Glass · BPE
Sight-glass family for visual observation of compatible hygienic process flow.
Specify the connection and operating duty, including the glass and seal limits. Confirm finish, drainage orientation and cleaning requirements.
Clean Steam Separation, Sampling & Injection
HSV · Hygienic Sampling Valve
Sampling-valve family for a compatible hygienic process sampling arrangement.
Specify sample fluid and conditions, connection, required cleaning or sterilisation method and sample handling. Confirm the actual valve configuration and seals.
SSI115 · Hygienic Steam Injector
Direct steam-injection equipment for compatible hygienic liquid-heating duties.
Confirm that direct steam contact suits the process. Provide liquid properties, heating load, steam quality and pressure, and installation geometry.
DSHS · Clean Steam Humidifier
Clean steam-injection equipment for an appropriate air-humidification application.
Provide airflow, duct geometry, humidity duty and steam conditions. Confirm distribution, absorption distance, condensate drainage and required materials.
MSAV · Atmospheric Tank Mushroom Vent
Mushroom-style vent for atmospheric tanks, with a cover and perforated barrier intended to limit entry of foreign matter through the vent connection.
Confirm required air exchange, connections and cleaning arrangement. Do not assume microbial-retention or sterile-filtration performance from this vent construction.
S10H · Clean Steam Moisture Separator
Moisture separator for a compatible clean steam pipeline duty.
Specify steam flow, pressure, required connection and installation layout. Select appropriate condensate drainage and verify the wetted finish and materials.
S10HV · Clean Steam Moisture Separator
Clean steam moisture-separation equipment with a model-specific connection and installation arrangement.
Use the S10HV drawing to confirm orientation and drainage. Size for steam flow and operating conditions and verify the required hygienic configuration.
S11 · Clean Steam Moisture Separator
Moisture-separation equipment for a compatible clean steam installation.
Confirm line arrangement, steam duty, pressure drop and condensate drainage using the S11 model document. Specify the required finish, connections and seals.
SC32P · Clean Steam Sample Cooler
Sample-cooling equipment for a compatible clean steam or process sampling arrangement.
Specify sample-side and cooling-water conditions, required sample outlet temperature and flow. Confirm wetted construction, connections and cleaning requirements.
Specify the Hygienic Configuration
Define the process fluid, cleaning and sterilisation conditions, wetted surface finish, elastomer requirements and drainability. Specify the actual connection standard and size; DIN and ASME BPE catalogue versions have different connection dimensions.
Request the material records, finish documentation and applicable compliance documents for the exact ordered configuration. A product-family name alone does not establish the documentation or suitability of every variant.
APPLICATION BEFORE SPECIFICATION
Selection Starts with Your Application
Specify the medium, operating conditions, connection type and standard, surface finish and documentation requirements, together with cleaning or sterilisation conditions. Confirm each model against the actual process and CIP/SIP requirements.
Catalogue & Technical Documents
Review the model-specific technical information and installation requirements. Send a specification, drawing or existing model reference if you need help selecting equipment.
Discuss Your Application
Send your requirements or a photo of the existing equipment for technical assistance and a quotation.
Availability and lead time are confirmed for the requested model and quantity.






